Fire Alarm Panels

ADDRESSABLE FIRE ALARM PANELS

£300.12£552.09

With a powerful one or two 40V 500mA loop drivers allowing the connection of up to 255CAST devices per loop, the installation of a cost effective, feature-packed addressable fire alarm system has never been easier. The panel is fully certified to EN54 parts 2, 4 and 13.

Features

• Two independently programmable conventional sounder circuits
•Two programmable inputs
•A fault output relay and three programmable relay outputs with voltage free changeover contacts
•A selection of zone dependency/coincidence functions
•A day/night (building occupied/unoccupied) function
•An investigation delay period function
•Phased evacuation facility
•An alarm counter that records how many times the panel has been in alarm state
•Powerful short circuit protected loop drivers
•An integral EN54-4/A2 switch mode
•Adjustable contamination levels
• Earth fault monitoring
• Combined keypad / keyswitch entry to Access Levels 2 and 3
• 500 event monitoring
• An intuitive Windows based upload-download PC program
• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel

PLEASE SPECIFY IF APOLLO XP95 PROTOCOL IS REQUIRED

Dimensions:

380mm x 235mm x 96mm

TO INCLUDE ADD-ONS ORDER SEPARATELY

ENTER: BLE

Clear selection

Description

The ADDRESSABLE FIRE ALARM PANEL is a powerful one or two 40V 500mA loop drivers allowing the connection of up to 255 CAST devices per loop. The installation of a cost effective, feature-packed addressable fire alarm system has never been easier. The panel is fully certified to EN54 parts 2, 4 and 13.

ADD-ONS

Product Details

Specification:

  • Mains Supply: 230V 50/60Hz
  • Mains Rated Current: 350mA maximum
  • Internal Power Supply: 27V DC Nominal
  • Total Output Current Limited to: 1.4A @ 230V AC (Imax.A 210mA; Imin. 40mA)
  • Max. Loop Output Current: 450mA (40V max)
  • Max. Loop Length: 1km
  • No. of Conventional Sounder Circuits: 2 (Max. length per circuit is 500m) EOL Resistor Value: 6800Ω 5% Tol. 0/25W (blue, grey, red, gold)
  • Max. Sounder Output Current: 400mA
  • Auxiliary Relays: 3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover.
  • Max. switch current 1A; Max. switch voltage 30V DC.
  • Other Outputs: 24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.
  • Auxiliary Inputs: 2 x Programmable Inputs (programmable from C&Es). Connect to 0V to
    trigger, Max. input voltage 27V (non-latching).
  • Connections: Fixed, largest acceptable conductor size 1mm²
  • Construction & Finish: Plastic Lid and Base, RAL7035 textured
  • IP Rating: IP30
  • Weight: 1.8kg (without batteries)
  • Operating Conditions/Temperature: -5ºC to +40ºC. Max Relative Humidity: 95%

Dimensions:

  • 380mm x 235mm x 96mm

Applications

  • Fire
  • Safety

Optional Extra

Code Repeater Panel
BFX/REP/16 Repeater Panel, 16 Zones (all protocols). Max. 2 x 3.2Ah Batteries
BFX/REP/32 Repeater panel, 32 Zones (all protocols). Max. 2 x 7.0Ah Batteries
BFX/NC/16 Network Communications Card for 16 Zone Panels
BFX/NC/32 Network Communications Card for 32 Zone Panels
BFX/REP/BEZEL/32 Flush Mounting Bezel (for 32 Zone Masters & Repeaters)
BF/PROG 2M Programming Lead (4 Way Molex to 9-Way RS232 ‘D’ female)
BFX-USB RS232 to USB Convertor
BFX/S-KEY Spare Key for use with Single Loop 16 Zone Panels
BFX-PROG CAST Handheld Programmer

Product Codes

Code Addressable Fire Panel
BFX/1/16 1 Loop 16 Zone Addressable Fire Panel (C-TEC CAST Protocol)
Quiescent Current: 50mA (loop unloaded) Max Battery Size and Type: 2 x 12V 3.2Ah VRLA
connected in series. No. of Loop Drivers: 1.
BFX/1/32 1 Loop 32 Zone Addressable Fire Panel (C-TEC CAST Protocol)
Quiescent Current: 80mA (loop unloaded) Max Battery Size and Type: 2 x 12V 7.0Ah VRLA
connected in series. No. of Loop Drivers: 1.
BFX/2/32 2 Loop 32 Zone Addressable Fire Panel (C-TEC CAST Protocol)
Quiescent Current: 100mA (2 loops unloaded) Max Battery Size and Type: 2 x 12V 7.0Ah VRLA
connected in series. No. of Loop Drivers: 2.

Download

ADDRESSABLE FIRE ALARM PANELS