STANDARD CONVENTIONAL FIRE ALARM PANELS BF2 – ADD ONS

£2.51£238.00

Our Standard Fire Alarm Panel is certified to EN54 parts 2 & 4 and offers an array of user and installer-friendly features. Supplied in an attractive flush or surface mountable plastic enclosure, it includes two, four or eight detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry. A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters, relay expansion boards and EN54-13 system compliance devices are also available.

Features

• Intuitive user-friendly interface with colourcoded buttons and combined keypad / keyswitch entry
• Four conventional sounder circuits
• Integral 1.5A EN54-4/A2 compliant switch mode PSU
• Wide range of engineering functions including zone test, coincidence, zone delay and nonlatching zones
• Two on-board relays (Fire and Fault)
• Two open-collector outputs (Remote and Reset)
• ’Class change’ and alert inputs
• Installer-friendly design
• Attractive flush or surface mountable plastic lid and enclosure – no bezel required
• Low 25mA quiescent current
• Multiple indicators
• System expansion connections provided for up to eight two-wire repeaters (One Network Card Required per system), optional relay boards and optional EN54-13 compliant sounder circuit boards

FOR BF2 STANDARD CONVENTIONAL FIRE ALARM PANELS ORDER SEPARATELY

Clear selection

Description

The STANDARD CONVENTIONAL FIRE ALARM Panels is certified to EN54 parts 2 & 4. It offers an array of user and installer-friendly features. Supplied in an attractive flush or surface mountable plastic case. It includes two, four or eight detector zones, four conventional sounder % circuits, class change and alert inputs, on-board fire and fault relays and a keypad/ key switch entry. A large range of engineering functions are also provided including many choices of zone delays and coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are provided. Options of extra repeaters and relay expansion boards and EN54-13 system compliance devices are also available.

STANDARD CONVENTIONAL FIRE ALARM Panels Alternatives:

Product Details

Specification:

  • Mains Supply: 230V 50/60Hz
  • Mains Rated Current: 350mA Max
  • Internal Power Supply: 19V-28.5V (27V nominal). Ripple 7V Max (Battery Fault)
  • Total Output Current Limited to: 1.5A @ 230V AC (ImaxA eq 146mA)
  • Quiescent Current: 25mA (Mains Failed, Internal Sounder Active, PSU & Gen Fault LED Lit)
  • Max Battery Size and Type: 2 x 12V 3.2Ah VRLA Connected in Series. Min. Battery Size 1.2Ah
  • Call Point Resistor Value: 470 to 680Ω
  • Max. Devices per Detector Zone: 25 Detectors (or 32 Detectors/Manual Call Points Combined)
  • No. of Conventional Sounder Circuits: 4 (Max. Length per Circuit is 500m)
  • Alarm Voltage: 27V Max, 20V Min (Final Battery Voltage)
  • Max. Sounder Output Current: 4 x 200mA (800mA total)
  • Construction / Finish: Plastic Lid and Base, RAL7035 Textured
  • IP Rating: IP30
  • Weight 1.75Kg (Without Batteries)
  • Operating Conditions / Temperature: -5ºC to +40ºC
  • Max Relative Humidity: 95%

Dimensions:

  • 380mm x 235mm x 96mm

Applications

  • Fire
  • Safety

Optional Extra

REPEATER PANELS

DESCRIPTION

2 ZONE – BF2/200/C 2 Zone Standard Fire Panel (requires BP24/2.1 Battery Pack)
2 ZONE – BP24/2.1 Sealed Lead Acid Battery Pack. 2 x 12V 2.1Ah Rated ( for BF2/200 Range)
4 ZONE – BF2/400/C 4 Zone Standard Fire Panel (requires BP24/2.1 Battery Pack)
4 ZONE – BP24/2.1 Sealed Lead Acid Battery Pack. 2 x 12V 2.1Ah Rated ( for BF2/200 Range)
8 ZONE – BF2/800/C 8 Zone Standard Fire Panel (requires BP24/2.8 Battery Pack)
8 ZONE – BP24/2.8 Sealed Lead Acid Battery Pack. 2 x 12V 2.8Ah Rated ( for BF2/200 Range)

Product Codes

REPEATER PANELS

DESCRIPTION

BF2/REP/C 8 Zone Repeater Panel. Max 2×3.2Ah Batteries. Requires BF2/NCC Card
BF2/NCC Network Driver Card for BF2/REP/C Panel (1 per repeater system)
BF2/ROC Relay Output Card (Reset, Fault, Auxillary and Remote Relay Outputs)
BF2/KS Fire Alarm Control Panel Mains Keyswitch
BF2/SK Spare Key for Main and Repeater Panels

 

Download